Evaluation of the Structural Performance of a Novel Methodology for Connecting Modular Units Using Straight and Cross-Shaped Connector Plates in Modular Buildings

Title
Evaluation of the Structural Performance of a Novel Methodology for Connecting Modular Units Using Straight and Cross-Shaped Connector Plates in Modular Buildings
Author
이강석
Keywords
modular structure; connection between modular units; connector plate; bolted connection; straight-shaped plate; cross-shaped plate
Issue Date
2020-11
Publisher
MDPI
Citation
APPLIED SCIENCES-BASEL, v. 10, Issue. 22, Article no. 8186, 18pp
Abstract
The strength capacity of modular buildings is determined by the weakest part, and connections between modular units are often weaker than the modular units themselves. Thus, to verify the safety of modular structures, the structural performance of connections between modular units should be evaluated
URI
https://www.mdpi.com/2076-3417/10/22/8186https://www.proquest.com/docview/2463794102?accountid=11283https://repository.hanyang.ac.kr/handle/20.500.11754/165196
ISSN
2076-3417
DOI
10.3390/app10228186
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > ARCHITECTURE(건축학부) > Articles