The AT Forward MRC is studied on the stability. The compensator is composed of the error amp with 3 poles and 2 zeros. This is optimized through the experiment. The converter loop gain is measured using HP4194A. We are initiated by the thinking of how to make the stabilization from the experimental results of loop gain curves. The loop gain, low frequency gain and gain margin are more improved through the experimental considerations.