220 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author전종수-
dc.date.accessioned2020-11-04T05:21:09Z-
dc.date.available2020-11-04T05:21:09Z-
dc.date.issued2019-11-
dc.identifier.citationCOMPOSITE STRUCTURES, v. 228, article no. 111328en_US
dc.identifier.issn0263-8223-
dc.identifier.issn1879-1085-
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0263822319315004?via%3Dihub-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/155200-
dc.description.abstractNon-ductile reinforced concrete building structures built before the 1970s have been significantly damaged and collapsed under man-made disasters (e.g., blast loads) due to their inadequate column details. The structural deficiencies can be mitigated by a fiber-reinforced polymer jacketing system. This research investigated the blast performance of a low-rise non-ductile building frame strengthened with the jacketing system. Based on the investigation, a retrofit scheme was established to mitigate the blast-induced damage and maximize the effectiveness of the retrofit system. The retrofitted models varied with the main parameters of the retrofit system associated with the confinement effect and flexural stiffness, and blast simulation was performed under various loading scenarios. The retrofit effect was examined in terms of confinement and stiffness ratios. Since the effects of the retrofit parameters on the blast performance depend on the blast loads, the retrofit scheme needs to be established in terms of expected blast loading scenarios.en_US
dc.description.sponsorshipThis work was supported by a Strategic Research Project, "BIM-GIS based Seismic Assessment and Management System for Building Structures" funded by the Korea Institute of Civil Engineering and Building Technology (KICT).en_US
dc.language.isoenen_US
dc.publisherELSEVIER SCI LTDen_US
dc.subjectBlast performanceen_US
dc.subjectNon-ductile reinforced concrete frameen_US
dc.subjectFiber-reinforced polymer jacketing systemen_US
dc.subjectRetrofit schemeen_US
dc.titleRetrofit scheme of FRP jacketing system for blast damage mitigation of non-ductile RC building framesen_US
dc.typeArticleen_US
dc.relation.volume228-
dc.identifier.doi10.1016/j.compstruct.2019.111328-
dc.relation.page1-14-
dc.relation.journalCOMPOSITE STRUCTURES-
dc.contributor.googleauthorShin, Jiuk-
dc.contributor.googleauthorJeon, Jong-Su-
dc.relation.code2019041355-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING-
dc.identifier.pidjongsujeon-
dc.identifier.orcidhttps://orcid.org/0000-0001-6657-7265-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > CIVIL AND ENVIRONMENTAL ENGINEERING(건설환경공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE