177 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김이석-
dc.date.accessioned2020-09-02T05:52:28Z-
dc.date.available2020-09-02T05:52:28Z-
dc.date.issued2019-08-
dc.identifier.citationARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, v. 139, no. 8, Page. 1149-1160en_US
dc.identifier.issn0936-8051-
dc.identifier.issn1434-3916-
dc.identifier.urihttps://link.springer.com/article/10.1007%2Fs00402-019-03214-7-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/153510-
dc.description.abstractIntroductionAcetabular revision arthroplasty using jumbo cups for moderate-to-severe acetabular defects has varied outcomes. We evaluated the clinical and radiological outcomes of acetabular revision arthroplasty using a press-fitted jumbo cup and sought to identify factors that influence outcomes during intermediate follow-up.Materials and methodsEighty patients (47 men, 33 women; 80 hips) who underwent acetabular revision arthroplasty using press-fitted jumbo cups were included. The mean follow-up period was 10.4years. Harris hip score (HHS), presence of groin pain, radiographic results, and Kaplan-Meier survival curves were evaluated. Implant design and surgery-related and patient-related factors were assessed to identify influential factors for cup loosening. Migration and wear analyses were performed using Einzel-Bild-Rontgen-Analyse software.ResultsThe mean preoperative HHS of 53 had improved to 77 at the final follow-up (p=0.005). Nine patients experienced groin pain. Acetabular cup loosening was observed in seven cups (8.7%), and one jumbo cup was replaced with a reinforcement cage. The survival rate of the acetabular cup was 91% at 16years according to the Kaplan-Meier analysis. Osteolysis was identified around the cup in six cases (7.5%). Acetabular cup loosening occurred more frequently in patients with conventional polyethylene liners than in those with highly cross-linked polyethylene liners (p=0.045). The mean total migration was 1.52mm, and the mean total wear was 0.98mm. There was a positive correlation between total migration and total wear (p=0.023; Spearman's rho=0.388). The mean wear rate of the patients with the cup inclination angle<50 degrees was significantly lower than those with the cup inclination angle>50 degrees (p=0.001). There were four cases of complications (three dislocations and one infection) that did not require revision surgery.ConclusionPress-fitted jumbo cups for acetabular revision arthroplasty exhibited encouraging results during follow-up for an average of 10years. Use of highly cross-linked polyethylene liners and proper placement of the acetabular component with an inclination angle<50 degrees may contribute to better clinical outcomes after acetabular revision arthroplasty with jumbo cups.en_US
dc.language.isoenen_US
dc.publisherSPRINGERen_US
dc.subjectAcetabular revisionen_US
dc.subjectJumbo cupen_US
dc.subjectMigrationen_US
dc.subjectWearen_US
dc.titleAcetabular revision arthroplasty using press-fitted jumbo cups: an average 10-year follow-up studyen_US
dc.typeArticleen_US
dc.relation.no8-
dc.relation.volume139-
dc.identifier.doi10.1007/s00402-019-03214-7-
dc.relation.page1149-1160-
dc.relation.journalARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY-
dc.contributor.googleauthorMoon, Jun-Ki-
dc.contributor.googleauthorRyu, Jaejoon-
dc.contributor.googleauthorKim, Yeesuk-
dc.contributor.googleauthorYang, Jae-Hyuk-
dc.contributor.googleauthorHwang, Kyu-Tae-
dc.contributor.googleauthorKim, Young-Ho-
dc.relation.code2019045029-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidestone96-
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE