Effect of fiber spacing on dynamic pullout behavior of multiple straight steel fibers in ultra-high-performance concrete

Title
Effect of fiber spacing on dynamic pullout behavior of multiple straight steel fibers in ultra-high-performance concrete
Author
류두열
Keywords
Ultra-high-performance concrete; Straight steel fiber; Pullout resistance; Fiber distance; Bundling effect; Loading rate effect
Issue Date
2019-06
Publisher
ELSEVIER SCI LTD
Citation
CONSTRUCTION AND BUILDING MATERIALS, v. 210, Page. 461-472
Abstract
In this study, the effects of fiber spacing and loading rate on the pullout behaviors of single and multiple straight steel fibers embedded in ultra-high-performance concrete (UHPC) were investigated. Hence, three different fiber spacings, corresponding to the fiber volume fractions of 1, 2, and 7%, and loading rates, i.e., quasi-static and impacts, were considered. Bundled fiber specimens were also fabricated and tested to examine the fiber bundling effect at both the static and impact loading conditions. The test results indicated that the pullout resistance of straight steel fibers in UHPC improved by increasing the loading rate, regardless of their number, spacing, and bundles. Approximately 33–68% greater bond strengths were obtained in the single fiber specimen compared to the multiple fiber specimens at both the static and impact loads. The fiber bundles deteriorated the static pullout resistance, whereas both positive and negative bundling effects were found on the interfacial bond strength and pullout energy, respectively, under the impact loads. The strongest rate sensitivity on the dynamic increase factors of the pullout parameters, such as bond strength, maximum fiber tensile stress, and pullout energy, was found as the fibers were bundled, followed by the single and multiple fiber specimens. For the case of multiple fiber specimens, the loading rate sensitivity increased by decreasing the fiber spacing in general, such that the multiple fibers with closer spacings, corresponding to 2 and 7% by volume, were more sensitive to the rate of loading than their counterparts with greater fiber spacings.
URI
https://www.sciencedirect.com/science/article/pii/S0950061819306610?via%3Dihubhttps://repository.hanyang.ac.kr/handle/20.500.11754/151483
ISSN
0950-0618; 1879-0526
DOI
10.1016/j.conbuildmat.2019.03.171
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE