226 141

Comparison of biosimilar CT-P10 and innovator rituximab in patients with rheumatoid arthritis: a randomized controlled Phase 3 trial

Title
Comparison of biosimilar CT-P10 and innovator rituximab in patients with rheumatoid arthritis: a randomized controlled Phase 3 trial
Author
유대현
Keywords
Rituximab; CT-P10; rheumatoid arthritis; equivalence; biosimilar
Issue Date
2018-08
Publisher
TAYLOR & FRANCIS INC
Citation
MABS, v. 10, no. 6, page. 934-943
Abstract
This multinational, randomized, double-blind trial, (ClinicalTrials.gov identifier NCT02149121) was designed to demonstrate equivalence in pharmacokinetics and efficacy between CT-P10 and innovator rituximab (RTX) in patients with rheumatoid arthritis (RA). Adults with active RA were treated with CT-P10, United States-sourced RTX (US-RTX; Rituxan (R)), or European Union-sourced RTX (EU-RTX; MabThera (R)) at weeks 0 and 2. The co-primary pharmacokinetic endpoints were area under the serum concentration-time curve (AUC) from time zero to last measurable concentration (AUC(0-last)), AUC from time zero to infinity (AUC(0-)), and maximum concentration (C-max) after two infusions. The primary efficacy endpoint was change from baseline to week 24 in Disease Activity Score using 28 joints-C-reactive protein (DAS28-CRP). Pharmacodynamics, immunogenicity, and safety were also assessed. 372 patients were randomly assigned to CT-P10 (n=161) or RTX (n=211 [US-RTX, n=151; EU-RTX, n=60]). For the co-primary pharmacokinetic endpoints, 90% confidence intervals (CI) for ratios of geometric means (CT-P10/US-RTX, CT-P10/EU-RTX or EU-RTX/US-RTX) all fell within the equivalence margin of 80-125%. Adjusted least squares (LS) mean (standard error) change from baseline in DAS28-CRP at week 24 was -2.13 (0.175) for CT-P10 and -2.09 (0.176) for RTX. The 95% CI (-0.29, 0.21) of the estimated treatment difference between CT-P10 and RTX (-0.04) was entirely within the efficacy equivalence margin of +/- 0.5. Pharmacodynamics, immunogenicity, and safety profiles were similar for CT-P10 and RTX. The pharmacokinetics of CT-P10, US-RTX, and EU-RTX were equivalent. CT-P10 and RTX were also equivalent in terms of efficacy and displayed similar pharmacodynamic, immunogenicity, and safety profiles up to week 24.
URI
https://www.tandfonline.com/doi/full/10.1080/19420862.2018.1487912https://repository.hanyang.ac.kr/handle/20.500.11754/119695
ISSN
1942-0862; 1942-0870
DOI
10.1080/19420862.2018.1487912
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
Comparison of biosimilar CT-P10 and innovator rituximab in patients with rheumatoid arthritis a randomized controlled Phase 3 trial.pdfDownload
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE