232 62

The Diagnostic Reproducibility of Tomosynthesis for the Correlation between Acromiohumeral Distance and Rotator Cuff Size or Type

Title
The Diagnostic Reproducibility of Tomosynthesis for the Correlation between Acromiohumeral Distance and Rotator Cuff Size or Type
Author
이봉근
Keywords
Shoulder; Shoulder impingement; Rotator cuff; Cuff arthropathy
Issue Date
2018-06
Publisher
KOREAN RADIOLOGICAL SOC
Citation
KOREAN JOURNAL OF RADIOLOGY, v. 19, no. 3, page. 417-424
Abstract
ObjectiveTo correlate the acromiohumeral distance (AHD) using tomosynthesis and rotator cuff (RC) pathology and various anatomical indices and to assess the diagnostic reproducibility of tomosynthesis for the evaluation of subacromial impingement.Materials and MethodsA retrospective review of 63 patients with clinically suspected subacromial impingement was conducted. Two musculoskeletal radiologists independently measured the following quantitative data: the AHD on plain radiographs and the AHD at three compartments (anterior, middle, and posterior) using tomosynthesis, computed tomography (CT) arthrography, or magnetic resonance (MR) arthrography. To investigate the association between the AHD and RC pathology and various anatomical indices, we reviewed the arthroscopic operation record as the referenced standard.ResultsThe size of rotator cuff tear (RCT) in full-thickness tears displayed a significant inverse correlation with the middle and the posterior tomosynthetic AHDs (p < 0.05). The results of an ANOVA revealed that the middle tomosynthetic AHD retained a significant association with the type of RCT (p = 0.042), and the posterior tomosynthetic AHD retained significance for the size of RCT in a full-thickness tear (p = 0.024). The inter-modality correlation exhibited significant agreement especially among the plain radiography, tomosynthesis, and CT or MR arthrography (p < 0.05). The intraobserver and interobserver correlation coefficients (ICCs) displayed excellent agreement (ICC = 0.896–0.983). The humeral head diameter and glenoid height were significantly correlated with patient height and weight.ConclusionAcromiohumeral distance measurement using tomosynthesis is reproducible compared with other modalities.
URI
https://kjronline.org/DOIx.php?id=10.3348/kjr.2018.19.3.417https://repository.hanyang.ac.kr/handle/20.500.11754/119203
ISSN
1229-6929; 2005-8330
DOI
10.3348/kjr.2018.19.3.417
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
The Diagnostic Reproducibility of Tomosynthesis for the Correlation between Acromiohumeral Distance and Rotator Cuff Size or Type.pdfDownload
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE