269 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김용수-
dc.date.accessioned2019-12-05T07:03:23Z-
dc.date.available2019-12-05T07:03:23Z-
dc.date.issued2018-02-
dc.identifier.citationJOURNAL OF ULTRASOUND IN MEDICINE, v. 37, no. 2, page. 355-362en_US
dc.identifier.issn0278-4297-
dc.identifier.issn1550-9613-
dc.identifier.urihttps://onlinelibrary.wiley.com/doi/full/10.1002/jum.14341-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/117468-
dc.description.abstractObjectives-To compare the diagnostic performance for advanced hepatic fibrosis measured by 2D shear-wave elastography (SWE), using either the coefficient of variance (CV) or the interquartile range divided by the median value (IQR/M) as quality criteria. Methods-In this retrospective study, from January 2011 to December 2013, 96 patients, who underwent both liver stiffness measurement by 2D SWE and liver biopsy for hepatic fibrosis grading, were enrolled. The diagnostic performances of the CV and the IQR/M were analyzed using receiver operating characteristic curves with areas under the curves (AUCs) and were compared by Fisher's Z test, based on matching the cutoff points in an interactive dot diagram. All P values less than 0.05 were considered significant. Results-When using the cutoff value IQR/M of 0.21, the matched cutoff point of CV was 20%. When a cutoff value of CV of 20% was used, the diagnostic performance for advanced hepatic fibrosis (>= F3 grade) with CV of less than 20% was better than that in the group with CV greater than or equal to 20% (AUC 0.967 versus 0.786, z statistic = 2.23, P = .025), whereas when the matched cutoff value IQR/M of 0.21 showed no difference (AUC 0.918 versus 0.927, z statistic = -0.178, P = .859). Conclusions-The validity of liver stiffness measurements made by 2D SWE for assessing advanced hepatic fibrosis may be judged using CVs, and when the CV is less than 20% it can be considered more reliable than using IQR/M of less than 0.21.en_US
dc.language.isoen_USen_US
dc.publisherWILEYen_US
dc.subjectelastographyen_US
dc.subjecthepatic fibrosisen_US
dc.subjecthepatobiliaryen_US
dc.subjectliver cirrhosisen_US
dc.subjectsonoelastographyen_US
dc.titleCoefficient of Variance as Quality Criterion for Evaluation of Advanced Hepatic Fibrosis Using 2D Shear-Wave Elastographyen_US
dc.typeArticleen_US
dc.relation.no2-
dc.relation.volume37-
dc.identifier.doi10.1002/jum.14341-
dc.relation.page355-362-
dc.relation.journalJOURNAL OF ULTRASOUND IN MEDICINE-
dc.contributor.googleauthorLim, Sanghyeok-
dc.contributor.googleauthorKim, Seung Hyun-
dc.contributor.googleauthorKim, Yongsoo-
dc.contributor.googleauthorCho, Young Seo-
dc.contributor.googleauthorKim, Tae Yeob-
dc.contributor.googleauthorJeong, Woo Kyoung-
dc.contributor.googleauthorSohn, Joo Hyun-
dc.relation.code2018001889-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidysookim-