349 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김종경-
dc.date.accessioned2019-11-30T08:01:22Z-
dc.date.available2019-11-30T08:01:22Z-
dc.date.issued2017-09-
dc.identifier.citationJOURNAL OF RADIOLOGICAL PROTECTION, v. 37, no. 3, page. 635-641en_US
dc.identifier.issn0952-4746-
dc.identifier.issn1361-6498-
dc.identifier.urihttps://iopscience.iop.org/article/10.1088/1361-6498/aa714d-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/115469-
dc.description.abstractRadioiodine can be released in nuclear accidents and can cause internal contamination of the thyroid gland in members of the public. For population monitoring in radiation emergencies, measurement of counting efficiency is very important to accurately determine thyroid activity. Here, we estimate the counting efficiencies of a portable NaI detector using Monte Carlo simulations. Two different types of neck phantoms and a 7.62 cm long by 7.62 cm diameter NaI detector were modeled and the counting efficiencies were calculated depending on the thyroid size and distance from the neck phantom to the detector. We found that distance is a more important parameter than thyroid size. The optimal distance of the NaI detector from the neck surface was determined to be greater than 12 cm, beyond which the counting efficiency was not affected by thyroid size.en_US
dc.description.sponsorshipThe authors would like to thank Anne Laure Lebacq of SCK-CEN for providing information about the family neck phantom used in this study. This study was supported by a grant of the Korea Institute of Radiological and Medical Sciences (KIRAMS), funded by Ministry of Science, ICT and Future Planning, Republic of Korea (1711045572/50445-2017).en_US
dc.language.isoen_USen_US
dc.publisherIOP PUBLISHING LTDen_US
dc.subjectcounting efficiencyen_US
dc.subjectNaI detectoren_US
dc.subjectMonte Carlo simulationen_US
dc.subjectthyroid measurementen_US
dc.subjectinternal contaminationen_US
dc.titleEstimation of counting efficiencies of a portable Nal detector using Monte Carlo simulation for thyroid measurement following nuclear accidentsen_US
dc.typeArticleen_US
dc.identifier.doi10.1088/1361-6498/aa714d-
dc.relation.journalJOURNAL OF RADIOLOGICAL PROTECTION-
dc.contributor.googleauthorHa, Wi-Ho-
dc.contributor.googleauthorKim, Jong Kyung-
dc.contributor.googleauthorJin, Young Woo-
dc.relation.code2017006727-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF NUCLEAR ENGINEERING-
dc.identifier.pidjkkim1-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > NUCLEAR ENGINEERING(원자력공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE