216 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author오재훈-
dc.date.accessioned2019-11-29T01:32:00Z-
dc.date.available2019-11-29T01:32:00Z-
dc.date.issued2017-08-
dc.identifier.citationBLOOD PRESSURE MONITORING, v. 22, no. 6, page. 364-370en_US
dc.identifier.issn1359-5237-
dc.identifier.issn1473-5725-
dc.identifier.urihttps://insights.ovid.com/crossref?an=00126097-201712000-00010-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/115120-
dc.description.abstractObjectiveIn this study, to measure blood pressure (BP) on the basis of human hearing threshold, we proposed a method that detects the audible or inaudible Korotkoff sounds (K-sounds) using the equal loudness contour and automatically assesses the BP.MethodsIn this study, we detected the systolic period of K-sounds using cuff pressure oscillation and then converted the K-sounds corresponding to the systolic interval into sound pressure levels (SPLs). Next, the systolic blood pressure (SBP) and diastolic blood pressure (DBP) were assessed by mapping the K-sounds, which were converted into SPLs on an equal loudness contour.ResultsTo validate the accuracy of our proposed method, we compared it with the auscultatory method. The mean differences (meanSD) in the SBP and DBP were 0.31 +/- 1.95 and 1.20 +/- 2.17mmHg, respectively. For the SBP, the linear regression equation was y=0.98x+1.56mmHg (where x and y represent the auscultatory and the proposed method, respectively), with a SE of estimate of 1.93mmHg and a correlation coefficient of 0.99. For the DBP, the linear regression equation was y=1.01x-1.94mmHg, with an SE of estimate of 2.18mmHg and a correlation coefficient of 0.98. All P values were less than 0.0001 for both regressions.ConclusionThe auscultatory method of BP monitoring is sensitive to the observer's condition or environmental noise. To overcome these disadvantages, we used the human hearing threshold for objective SBP and DBP automatic assessment, and this method can be applicable to an automatic auscultatory method. Copyright (C) 2017 Wolters Kluwer Health, Inc. All rights reserved.en_US
dc.description.sponsorshipThis research was supported by the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Education (NRF-2015M3C7A1064789) and Institute for Information & communications Technology Promotion (IITP) grant funded by the Korea government (MSIP) (10045452).en_US
dc.language.isoen_USen_US
dc.publisherLIPPINCOTT WILLIAMS & WILKINSen_US
dc.subjectauscultationen_US
dc.subjectblood pressureen_US
dc.subjecthuman hearing thresholden_US
dc.subjectKorotkoff soundsen_US
dc.subjectsound pressure levelen_US
dc.titleAutomatic assessment of blood pressure for Korotkoff sounds on the basis of human hearing thresholden_US
dc.typeArticleen_US
dc.relation.no6-
dc.relation.volume22-
dc.identifier.doi10.1097/MBP.0000000000000284-
dc.relation.page364-370-
dc.relation.journalBLOOD PRESSURE MONITORING-
dc.contributor.googleauthorHong, Sung Jun-
dc.contributor.googleauthorLee, Jong Shill-
dc.contributor.googleauthorOh, Jae Hoon-
dc.contributor.googleauthorChee, Young Joon-
dc.contributor.googleauthorJang, Dong Pyo-
dc.contributor.googleauthorKim, In Young-
dc.relation.code2017009236-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidojjai-
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE