Feasibility of Reducing Differences in Estimated Doses in Nuclear Medicine Between A Patient-specific and A Reference Phantom

Title
Feasibility of Reducing Differences in Estimated Doses in Nuclear Medicine Between A Patient-specific and A Reference Phantom
Author
김찬형
Keywords
Nuclear medicine; Human computational phantom; Personalised internal dose; Cross-fire
Issue Date
2017-07
Publisher
ELSEVIER SCI LTD
Citation
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, v. 39, page. 100-112
Abstract
The feasibility of reducing the differences between patient-specific internal doses and doses estimated using reference phantoms was evaluated. Relatively simple adjustments to a polygon-surface ICRP adult male reference phantom were applied to fit selected individual dimensions using the software Rhinoceros (R) 4.0. We tested this approach on two patient-specific phantoms: the biggest and the smallest phantoms from the Helmholtz Zentrum Munchen lib. These phantoms have unrelated anatomy and large differences in body-mass-index. Three models approximating each patient's anatomy were considered: the voxel and the polygon-surface ICRP adult male reference phantoms and the adjusted polygonsurface reference phantom. The Specific Absorbed Fractions (SAFs) for internal photon and electron sources were calculated with the Monte Carlo code EGSnrc. Employing the time-integrated activity coefficients of a radiopharmaceutical (S)-4-(3-18F-fluoropropyl)-L-glutamic acid and the calculated SAFs, organ absorbed-dose coefficients were computed following the formalism promulgated by the Committee on Medical Internal Radiation Dose. We compared the absorbed-dose coefficients between each patient-specific phantom and other models considered with emphasis on the cross-fire component. The corresponding differences for most organs were notably lower for the adjusted reference models compared to the case when reference models were employed. Overall, the proposed approach provided reliable dose estimates for both tested patient-specific models despite the pronounced differences in their anatomy. To capture the full range of inter-individual anatomic variability more patient-specific phantoms are required. The results of this test study suggest a feasibility of estimating patient-specific doses within a relative uncertainty of 25% or less using adjusted reference models, when only simple phantom scaling is applied. (C) 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
URI
https://www.physicamedica.com/article/S1120-1797(17)30193-X/fulltexthttps://repository.hanyang.ac.kr/handle/20.500.11754/114966
ISSN
1120-1797; 1724-191X
DOI
10.1016/j.ejmp.2017.06.003
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > NUCLEAR ENGINEERING(원자력공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE