250 0

Measurement of change on medial and lateral joint gaps by navigation system in multi-radius PS TKA

Title
Measurement of change on medial and lateral joint gaps by navigation system in multi-radius PS TKA
Author
최충혁
Keywords
TOTAL KNEE ARTHROPLASTY; TOURNIQUET; KINEMATICS
Issue Date
2017-07
Publisher
ELSEVIER SCIENCE BV
Citation
JOURNAL OF ORTHOPAEDIC SCIENCE, v. 22, no. 4, page. 693-697
Abstract
Background: The purpose of this study was to evaluate the joint gap kinematics in posterior-stabilized total knee arthroplasty (PS TKA).Methods: Between January 2010 and April 2011, 44 consecutive patients (55 knees) who underwent primary PS TKA using the navigation system were assessed. There were 37 women and 7 men with a mean age at operation of 63 years (range; 58-73 years). After fixation of all components with cement and insertion of polyethylene trial insert, medial and lateral joint gap measurements were carried out without distraction force and separately using a navigation system on each flexion angles. The joint gaps were measured before and after deflation of tourniquet, first with patella everted and then reduced.Results: Deflation of tourniquet did not effect on gap. In patellofemoral joint reduction situation, the medial gap relatively maintained throughout the range of knee motion, but the lateral gap is gradually decreasing with knee flexion from 30 degrees to 120 degrees flexion. However, in patellar eversion situation, the medial gap showed a significant increase and also statistically significantly increased compared with patellar reduced position over 90 degrees knee flexion status, but the lateral gaps are decreased compared with patellofemoral reduction situation throughout the range of knee motion except full flexion status. In more physiologic status that is patella reduced and tourniquet deflated status, the average medial joint gap change was 2.30 +/- 1.64 mm and the average lateral joint gap change was 2.90 +/- 1.53 mm throughout the range of motion.Conclusions: Medial and lateral joint gaps showed different patterns with patellar eversion and patellofemoral joint reduction. However, such changes occurred within 3 mm in average throughout whole range of knee motion even with multi-radius femoral component. (C) 2017 The Japanese Orthopaedic Association. Published by Elsevier B.V. All rights reserved.
URI
https://www.sciencedirect.com/science/article/pii/S0949265817300672?via%3Dihubhttps://repository.hanyang.ac.kr/handle/20.500.11754/114941
ISSN
0949-2658; 1436-2023
DOI
10.1016/j.jos.2017.02.010
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE