222 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김기현-
dc.date.accessioned2019-11-27T00:33:53Z-
dc.date.available2019-11-27T00:33:53Z-
dc.date.issued2017-07-
dc.identifier.citationENVIRONMENTAL MONITORING AND ASSESSMENT, v. 189, no. 7, Article no. 317en_US
dc.identifier.issn0167-6369-
dc.identifier.issn1573-2959-
dc.identifier.urihttps://link.springer.com/article/10.1007%2Fs10661-017-6024-1-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/114906-
dc.description.abstractTo develop accurate quantitation methods for two major permanent gases, N-2 and O-2, a series of calibration experiments were carried out using a gas chromatograph (GC)/barrier discharge ionization detector (BID) equipped with a large-volume injection (LVI) system. To this end, gaseous working standards (WSs) diluted with helium gas were prepared at ten different concentration levels representing three different concentration ranges (in ppm) in 1-L polyester aluminum (PEA) bags ((1) low, 209 similar to 2090 (O-2) and 791 similar to 7910 (N-2); (2) moderate, 2090 similar to 20,900 (O-2) and 7910 similar to 79,100 (N-2); and (3) high, 20,900 similar to 209,000 (O-2) and 79,100 similar to 791,000 (N-2)). Cross-calibration experiments for each individual WS were carried out using the loop injection system with four different capacities (0.01, 0.5, 1, and 10 mL). The calibration results were then evaluatedwith respect to key variables including loop capacity, concentration, and mass quantity. Accordingly, we observed the optimal performance of the BID in terms of sensitivity and linearity (R-2 > 0.98) when the WS of the moderate concentration range was analyzed with the small loop (0.01 and 0.5 mL). The method detection limit (MDL) values of the four loop sizes (between 0.01 and 10 mL) were 7 similar to 500 ng for O-2 (38.4 similar to 557 ppm) and 24 similar to 2230 ng for N-2 (195 similar to 2105 ppm).en_US
dc.description.sponsorshipThe corresponding author (KHK) acknowledges support made in part by grants from the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT & Future Planning (No. 2016R1E1A1A01940995).en_US
dc.language.isoen_USen_US
dc.publisherSPRINGERen_US
dc.subjectPermanent gasen_US
dc.subjectBarrier discharge ionization detectoren_US
dc.subjectLarge-volume injection systemen_US
dc.subjectCalibrationen_US
dc.subjectPolyester aluminum bagen_US
dc.titleThe applicability of a large-volume injection (LVI) system for quantitative analysis of permanent gases O-2 and N-2 using a gas chromatograph/barrier discharge ionization detectoren_US
dc.typeArticleen_US
dc.relation.no7-
dc.relation.volume189-
dc.identifier.doi10.1007/s10661-017-6024-1-
dc.relation.page1-10-
dc.relation.journalENVIRONMENTAL MONITORING AND ASSESSMENT-
dc.contributor.googleauthorJo, Sang-Hee-
dc.contributor.googleauthorKim, Ki-Hyun-
dc.relation.code2017007996-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING-
dc.identifier.pidkkim61-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > CIVIL AND ENVIRONMENTAL ENGINEERING(건설환경공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE