230 0

Successful outcome with minimally invasive plate osteosynthesis for periprosthetic tibial fracture after total knee arthroplasty

Title
Successful outcome with minimally invasive plate osteosynthesis for periprosthetic tibial fracture after total knee arthroplasty
Author
박기철
Keywords
Total knee arthroplasty; Periprosthetic tibial fracture; Minimally invasive plate osteosynthesis; Locking plate
Issue Date
2017-04
Publisher
ELSEVIER MASSON
Citation
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, v. 103, no. 2, page. 263-268
Abstract
Introduction: The incidence of periprosthetic fractures after total knee arthroplasty (TKA) is increasing, and treatment is becoming more necessary. In periprosthetic tibial fractures, the stem of the tibial component largely occupies the medullary canal of the proximal tibia, which limits the selection of implants. The purpose of this study was to evaluate the effectiveness of the minimally invasive plate osteosynthesis (MIPO) technique with locking plates for periprosthetic tibial fractures after TKA. Materials and methods: Sixteen patients with periprosthetic tibial fracture after TKA were included. There were 6 type II and 10 type III fractures according to the Felix classification. Ten patients had fractures in the proximal metaphysis, and 6 in the diaphysis. MIPO using locking plates was performed on the medial side in 4 cases, the lateral side in 2 cases, and both in 10 cases. Radiographic results included time to union, alignment, and malunion. Clinical results included range of motion (ROM), functional activity data, Knee Society scores, and complications. Results: Fourteen of 16 fractures achieved union at 17.1 weeks (range, 14-24) postoperatively. There were 2 failures that required a secondary procedure. Except one for 1 case with varus malunion, all had acceptable alignment. Mean ROM at the final follow-up was 108.8 degrees (range, 15-135 degrees), and 15 patients recovered pre-injury knee joint activity. Mean knee and function scores were 88.9 (range, 77-100) and 83.3 (range, 60-100), respectively. Knees with fewer than 8 cortices giving purchase to screws in the proximal segment showed higher failure rates (p = 0.025).Discussion: MIPO with locking plates can achieve satisfactory results for periprosthetic tibial fractures after TKA. Rigid fixation of the proximal segment may be necessary for successful outcome. (C)2016 Elsevier Masson SAS. All rights reserved.
URI
https://www.sciencedirect.com/science/article/pii/S1877056816302183?via%3Dihubhttps://repository.hanyang.ac.kr/handle/20.500.11754/113733
ISSN
1877-0568
DOI
10.1016/j.otsr.2016.10.007
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.