182 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author류두열-
dc.date.accessioned2019-10-29T05:49:43Z-
dc.date.available2019-10-29T05:49:43Z-
dc.date.issued2019-05-
dc.identifier.citationCONSTRUCTION AND BUILDING MATERIALS, v. 206, Page. 46-61en_US
dc.identifier.issn0950-0618-
dc.identifier.issn1879-0526-
dc.identifier.urihttps://www.sciencedirect.com/science/article/pii/S0950061819303526?via%3Dihub-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/111629-
dc.description.abstractThis study investigates the effects of steel fiber type on the pullout and tensile performance of ultra-high-performance fiber-reinforced concrete (UHPFRC). For this, four different types of steel fibers, i.e., straight, twisted, hooked, and half-hooked, were used. In order to consider random fiber orientation in UHPFRC, various inclination angles, ranging from 0° to 60°, were considered for the pullout tests. Test results indicated that better pullout resistance was obtained in the deformed (twisted, hooked, and half-hooked) steel fibers embedded in ultra-high-performance concrete (UHPC) than that of the straight steel fiber as fiber breakage was prevented. The highest bond strengths of all steel fiber types were found when they were inclined 30° or 45°, while their slip capacities increased with increasing inclination angle. The hooked steel fiber exhibited the highest bond strengths at all inclination angles, while the twisted and half-hooked steel fibers exhibited the highest pullout energies at aligned and highly inclined (45° and 60°) conditions, respectively. In contrast to the pullout test results, the best tensile performance of UHPFRC was achieved by incorporating straight steel fibers, followed by the twisted, half-hooked, and hooked steel fibers. The poorer tensile performance of UHPCs reinforced with the deformed steel fibers was because of the severe matrix damage from excessive mechanical anchorage and fiber congestion, leading to insufficient matrix volume. Similarly, a relatively weak correlation between the fiber pullout and tensile behaviors of UHPFRC was observed. Therefore, a new pullout test method, which is able to consider the fiber random orientation and spacing, is required in order to improve the correlation.en_US
dc.description.sponsorshipThis work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIT) (No. 2017R1C1B2007589).en_US
dc.language.isoenen_US
dc.publisherELSEVIER SCI LTDen_US
dc.subjectUltra-high-performance concreteen_US
dc.subjectSteel fibersen_US
dc.subjectPullouten_US
dc.subjectTensile performanceen_US
dc.subjectMatrix damageen_US
dc.subjectCorrelation between pullout and tensile testsen_US
dc.titleAn experimental study on pullout and tensile behavior of ultra-high-performance concrete reinforced with various steel fibersen_US
dc.typeArticleen_US
dc.relation.volume206-
dc.identifier.doi10.1016/j.conbuildmat.2019.02.058-
dc.relation.page46-61-
dc.relation.journalCONSTRUCTION AND BUILDING MATERIALS-
dc.contributor.googleauthorYoo, Doo-Yeol-
dc.contributor.googleauthorKim, Soonho-
dc.contributor.googleauthorKim, Jae-Jin-
dc.contributor.googleauthorChun, Booki-
dc.relation.code2019041376-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF ARCHITECTURAL ENGINEERING-
dc.identifier.piddyyoo-
dc.identifier.orcidhttp://orcid.org/0000-0003-2814-5482-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE