221 0

Setting up/down step-size in open loop power control for WiBro reverse link

Title
Setting up/down step-size in open loop power control for WiBro reverse link
Author
김동우
Issue Date
2007-09
Publisher
IEEE
Citation
2007 IEEE 18th International Symposium on Personal, Indoor and Mobile Radio Communications, Page. 1-5
Abstract
In this paper, we describe how to set up/down step-size in open loop power control for WiBro reverse link. Since open loop power control does not use feedback information, it is difficult to efficiently use wireless resource with accurate power control. We also provide a method of estimating levels of noise and interference. With numerical investigation, asymmetric up/down power-control step-size is shown to be promising to achieve high sector throughput as well as low error rate.