Full metadata record
DC Field | Value | Language |
---|---|---|
dc.contributor.author | 신성우 | - |
dc.date.accessioned | 2019-04-29T05:05:07Z | - |
dc.date.available | 2019-04-29T05:05:07Z | - |
dc.date.issued | 2016-10 | - |
dc.identifier.citation | 대한건축학회 2016년도 추계학술발표대회논문집, v. 36, No. 2, Page. 786-787 | en_US |
dc.identifier.issn | 2287-5786 | - |
dc.identifier.uri | http://www.dbpia.co.kr/Journal/ArticleDetail/NODE07156132 | - |
dc.identifier.uri | https://repository.hanyang.ac.kr/handle/20.500.11754/102894 | - |
dc.description.abstract | Codification of wind loads considering wind-induced interference effects is an issue in wind engineering as ever. It is difficult to codify a guideline because of the large number of variables involved. Apart from this difficulty and complexity, generalized and simplified guidelines for structural design wind loads will be useful in estimating approximate structural wind loads on tall buildings in preliminary design. The purpose of this study is to tackle the problem of wind-induced interference effects between two tall buildings to establish a generalized set of guidelines. The interference effects between two buildings were investigated by a series of deliberate wind tunnel tests. Various types of adjacent buildings were considered with breadth and height ratios. To reach critical conclusions being used to improve a design code, design interference factor for extreme base bending moment responses was suggested for the assessment of wind-induced interference effects between two tall buildings. | en_US |
dc.language.iso | ko_KR | en_US |
dc.publisher | 대한건축학회 | en_US |
dc.subject | 상호간섭효과 | en_US |
dc.subject | 구조설계용풍하중 | en_US |
dc.subject | 고층건축물 | en_US |
dc.subject | 풍동실험 | en_US |
dc.subject | Interference Effect | en_US |
dc.subject | Structural Design Wind Load | en_US |
dc.subject | Tall Building | en_US |
dc.subject | Wind Tunnel Test | en_US |
dc.title | 상호간섭효과를 고려한 고층건축물의 구조설계용 풍하중의 일반화에 관한 연구 | en_US |
dc.title.alternative | A Study on Generalization of Structural Design Wind Loads of A Tall Building considering Interference Effects | en_US |
dc.type | Article | en_US |
dc.relation.page | 786-787 | - |
dc.contributor.googleauthor | 김원술 | - |
dc.contributor.googleauthor | 이종원 | - |
dc.contributor.googleauthor | 김대홍 | - |
dc.sector.campus | E | - |
dc.sector.daehak | COLLEGE OF ENGINEERING SCIENCES[E] | - |
dc.sector.department | DIVISION OF ARCHITECTURE | - |
dc.identifier.pid | swshin | - |
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.