dc.description.abstractThe purpose of this paper is to analyze the operating energy consumption and performance of a liquid desiccant and evaporative cooling-assisted 100% outdoor air system (LD-IDECOAS) applied in an underwater building. Due to distinct features in surrounding environments of the underwater building from an above ground building, the thermal loads of the underwater building showed difference which affected the energy consumptions of the buildings accordingly. To estimate the energy consumption of the LD-IDECOAS, the office buildings located above the ground and underwater were assumed to be 625㎡ in size and have accommodations for 32 people. The thermal loads of the designed buildings were calculated using TRNSYS 17. According to the required thermal load of the modeling space, the energy simulation was conducted to evaluate the annual operating energy of the LD-IDECOAS using a commercial engineering equation solver (EES). As a result, the LD-IDECOAS in the underwater building showed 48% reduction in the energy consumption compared to that in the above ground building. Furthermore, the system performance was increased and the system capacity was reduced.en_US
dc.description.sponsorship이 논문은 2016년도 미래창조과학부의 재원으로 한국연구재단의 지원을 받아 수행된 연구임 (No. 2015R1A2A1A005001726). 또한, 2016년도 국토교통과학기술진흥원의 국토교통기술촉진연구사업 지원에 의해 수행되었음(16CTAP-C116268-01).en_US
dc.language.isoko_KRen_US
dc.publisher한국건축친환경설비학회en_US
dc.subject액체식 제습시스템en_US
dc.subject수중건물en_US
dc.subject전외기 공조시스템en_US
dc.subject증발냉각 시스템en_US
dc.subject건물에너지en_US
dc.subjectLiquid desiccant systemen_US
dc.subjectUnderwater buildingen_US
dc.subjectOutdoor air systemen_US
dc.subjectEvaporative cooling systemen_US
dc.subjectBuilding energyen_US
dc.title수중건물에 적용된 액체식 제습증발냉각기반 전외기 공조시스템의 연간 에너지 소비 및 성능 분석en_US
dc.title.alternativeAnnual Energy Consumption and Performance Analysis of a Liquid Desiccant and Evaporative Cooling-assisted 100% Outdoor Air System in an Underwater Buildingen_US
dc.typeArticleen_US
dc.relation.no6-
dc.relation.volume10-
dc.relation.page456-461-
dc.relation.journal한국건축친환경설비학회 논문집-
dc.contributor.googleauthor조민석-
dc.contributor.googleauthor박준영-
dc.contributor.googleauthor신장훈-
dc.contributor.googleauthor최병남-
dc.contributor.googleauthor정재원-
dc.contributor.googleauthorJo, Min-Suk-
dc.contributor.googleauthorPark, Joon-Young-
dc.contributor.googleauthorShin, Jang-Hoon-
dc.contributor.googleauthorChoi, Byoung-Nam-
dc.contributor.googleauthorJeong, Jae-Weon-
dc.relation.code2016018771-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF ARCHITECTURAL ENGINEERING-
dc.identifier.pidjjwarc-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > ARCHITECTURAL ENGINEERING(건축공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE