457 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author박노혁-
dc.date.accessioned2019-04-01T02:36:45Z-
dc.date.available2019-04-01T02:36:45Z-
dc.date.issued2015-01-
dc.identifier.citationACTA RADIOLOGICA, Vol.57, No.11, Page.1372-1379en_US
dc.identifier.issn0284-1851-
dc.identifier.issn1600-0455-
dc.identifier.urihttps://journals.sagepub.com/doi/abs/10.1177/0284185114568048?journalCode=acrc-
dc.identifier.urihttps://repository.hanyang.ac.kr/handle/20.500.11754/101363-
dc.description.abstractBackground There has been no comparison study to assess the diagnostic efficacy of additional anterior cruciate ligament (ACL) views in three-dimensional (3D) volume isotropic turbo spin-echo acquisition (VISTA) and two-dimensional (2D) fast spin-echo (FSE) T2-weighted (T2W) images for the diagnosis of ACL tear. Purpose To compare the diagnostic performances of additional ACL views on VISTA with those on the 2D FSE T2W images. Material and Methods This retrospective study included 78 patients who were suspected to have ACL injury and underwent both 2D TSE T2W magnetic resonance imaging (MRI) and 3D VISTA MRI of the knee between November 2012 and March 2013. The diagnostic performance of each oblique sagittal and coronal view and the combined images was evaluated for sensitivity, specificity, and accuracy for diagnosing an ACL tear. The arthroscopically and clinically confirmed diagnoses were used as the reference standard. The values were statistically analyzed using the McNemar test. Results The inter-observer agreement between two readers of the additional ACL views on 3D VISTA and 2D FSE T2W images were substantial on 2D FSE images and nearly concurred on the VISTA image. When considering both views of the oblique sagittal and coronal images, the inter-observer agreement between readers nearly concurred. There were no statistically significant differences in the sensitivity, specificity, and accuracy between 2D FSE images and VISTA images. Conclusion The performance of the additional ACL view on 3D VISTA MRI is comparable to that of 2D FSE T2W MRI in the diagnosis of ACL tear though the image quality of the 3D VISTA MRI is not equal to that of 2D FSE MRI.en_US
dc.description.sponsorshipThe author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: This work was supported by Samsung Biomedical Research Institute grant, #SMX1132241.en_US
dc.language.isoenen_US
dc.publisherSAGE PUBLICATIONS LTDen_US
dc.subjectMagnetic resonance imaging (MRI)en_US
dc.subjectkneeen_US
dc.subjectanterior cruciate ligament (ACL)en_US
dc.subject3D isotropicen_US
dc.subjectVISTAen_US
dc.titleThree-dimensional isotropic T2-weighted fast spin-echo (VISTA) knee MRI at 3.0 T in the evaluation of the anterior cruciate ligament injury with additional views: comparison with two-dimensional fast spin-echo T2-weighted sequencesen_US
dc.typeArticleen_US
dc.identifier.doi10.1177/0284185114568048-
dc.relation.journalACTA RADIOLOGICA-
dc.contributor.googleauthorPark, Hee Jin-
dc.contributor.googleauthorLee, So Yeon-
dc.contributor.googleauthorPark, Noh Hyuck-
dc.contributor.googleauthorAhn, Jin Hwan-
dc.contributor.googleauthorChung, Eun Chul-
dc.contributor.googleauthorKim, Sung Jun-
dc.contributor.googleauthorCha, Jang Gyu-
dc.relation.code2016001725-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidnhpark904-
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE