dc.description.abstractBlended cement is widely used in critical structures mainly because of its enhanced corrosion resistance concerning its durability. This paper presents the long term corrosion performance of blended cements namely; Portland pozzolana cement (PPC) and Portland slag cement (PSC) concrete under the three marine exposure conditions such as, atmospheric zone (AZ), immersion zone (IZ) and splash zone (SZ). Offshore Platform Marine Electrochemistry Center (OPMEC), Tuticorin, Tamil Nadu, India was selected as an exposure station. The concrete cubes were exposed over the period of 10 years and their physicochemical properties such as compressive strength, alkalinity, free chloride content and sulphate content, bio-fouling attachment and electrochemical properties like, AC-impedance and potentiodynamic polarization were carried out and the results obtained were compared with Ordinary Portland Cement (OPC) concrete. XRD and SEM studies were also carried out for both OPC, PPC and PSC concrete samples exposed under various zones. It was observed that the strength and alkalinity of the blended cement concretes were relatively equal to that of OPC concrete. In addition, the pH values of the blended cement concretes are above the threshold limit recommended for depassivation. Furthermore, the resistance to chloride ion penetration was significantly reduced for blended cement concretes than that of OPC concrete and also exhibited very high amount of bio-fouling attachment. The electrochemical studies revealed that the blended cement concretes are having higher corrosion resistance in all three exposure zones than that of OPC concrete. From the results it is observed that the blended cement concretes are technically viable from the durability point of view and highly recommended for aggressive marine environments rather than OPC concrete. (C) 2017 Elsevier Ltd. All rights reserved.en_US
dc.description.sponsorshipThis research was supported by the Basic Science Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT, & Future Planning (No. 2015R1A5A1037548). One of the authors (V.S) thanks the Director, CECRI, and CSIR for the permission to pursue my fellowship at Hanyang University, Korea.en_US
dc.language.isoen_USen_US
dc.publisherELSEVIER SCI LTDen_US
dc.subjectBlended cementsen_US
dc.subjectConcreteen_US
dc.subjectCorrosionen_US
dc.subjectMarine environmenten_US
dc.subjectConcrete exposureen_US
dc.subjectChlorideen_US
dc.subjectSulphateen_US
dc.titleLong-term corrosion performance of blended cement concrete in the marine environment - A real-time studyen_US
dc.typeArticleen_US
dc.relation.volume154-
dc.identifier.doi10.1016/j.conbuildmat.2017.07.237-
dc.relation.page349-360-
dc.relation.journalCONSTRUCTION AND BUILDING MATERIALS-
dc.contributor.googleauthorKwon, Seung-Jun-
dc.contributor.googleauthorLee, Han-Seung-
dc.contributor.googleauthorKarthick, Subbiah-
dc.contributor.googleauthorSaraswathy, Velu-
dc.contributor.googleauthorYang, Hyun-Min-
dc.relation.code2017006317-
dc.sector.campusE-
dc.sector.daehakCOLLEGE OF ENGINEERING SCIENCES[E]-
dc.sector.departmentDIVISION OF ARCHITECTURE-
dc.identifier.pidercleehs-
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > ARCHITECTURE(건축학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE