509 0

An experimental study on removal of exhaust gas recirculation cooler fouling using washer fluid steam

Title
An experimental study on removal of exhaust gas recirculation cooler fouling using washer fluid steam
Author
이기형
Keywords
Soot; EGR cooler; Diesel engine; Fouling; Particulate matter; Steam soot blower
Issue Date
2017-05
Publisher
PERGAMON-ELSEVIER SCIENCE LTD
Citation
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, v. 108, Page. 301-308
Abstract
Lowering the temperature of recirculated gas in an exhaust gas recirculation (EGR) system reduces the emission of nitrogen oxide (NOx). However, the EGR cooler can become polluted by PM in recirculated EGR gas, which reduces the cooling efficiency and the gas flow rate. A steam EGR cooler fouling remover (SECFR) system was designed using evaporated washer fluid to remove fouling on the cooler surface. However, the injection pressure is only 5 bar, which is not sufficient to atomize the washer fluid. Therefore, in this study, an impinging plate was used to promote the atomization of sprayed washer fluid, and the droplet area ratio (DAR) and droplet uniformity index (DUI) were measured through quantitative analysis of high-speed images. Finally, the performance. of the SECFR system was evaluated in a real diesel engine. (C) 2016 Elsevier Ltd. All rights reserved.
URI
https://www.sciencedirect.com/science/article/pii/S0017931016319895https://repository.hanyang.ac.kr/handle/20.500.11754/72093
ISSN
0017-9310
DOI
10.1016/j.ijheatmasstransfer.2016.12.009
Appears in Collections:
COLLEGE OF ENGINEERING SCIENCES[E](공학대학) > MECHANICAL ENGINEERING(기계공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE