dc.description.abstractPurpose: To study computerized measurements of angular parameters on 100% and 150% resized digital radiography of hallux valgus deformity Materials and Methods: 30 digital radiography of standing foot anteroposterior view of hallux valgus patients were included. Two observers(A, B) independently measured hallux valgus angle (HVA), 1-2 intermetatarsal angle (IMA), and distal metatarsal articular angle (DMAA) in two times on both 100%-size and 150% magnified images respectively, using computerized measurement software tools. The results were interpreted with the statistical software program, Statistical Analysis System, version 9.2.Results: In repeated measurements of each observer, measurements on 150% magnified image showed no differences of all three parameters and with 100%-size image, there were differences of HVA (observer A) and 1-2 IMA (observer B) (p>0.05). When testing interobserver reliability, both observers showed differences in measurement of HVA and DMAA (p<0.05), but no differences in measurement of 1-2 IMA in both images. Within the 95% confidence interval, limits of error of measurements between two observers on HVA, IMA and DMAA were 2.7° 1.4° and 5.0° respectively in 100%-size images, and 2.6°, 1.6° and 4.7° respectively in 150% magnified images.Conclusion: In computerized measurements for angular parameters of hallux valgus with digital radiography, 150% magnified images showed intraobserver reliability. Both 100% and 150% magnified images failed to show interobserver reliability.Measurement of 1-2 IMA in both 100% and 150% images showed less interobserver error.en_US
dc.language.isoko_KRen_US
dc.publisher대한족부족관절학회en_US
dc.subject무지외반en_US
dc.subject각변형en_US
dc.subject전산화계측en_US
dc.subject변형각en_US
dc.subjectHallux valgusen_US
dc.subjectAngular parametersen_US
dc.subjectComputerized measurementen_US
dc.title무지 외반증 각변형에 대한 디지털영상의 전산화 계측: 100%와 150% 확대영상에서의 계측비교en_US
dc.title.alternativeComputerized Measurement on Angular Parameters for Hallux Valgus: Comparison of 100% and 150% Magnified Digital Radiographyen_US
dc.typeArticleen_US
dc.relation.no1호-
dc.relation.volume16권-
dc.relation.page53-58-
dc.relation.journal대한족부족관절학회지-
dc.contributor.googleauthor성일훈-
dc.contributor.googleauthor이두연-
dc.contributor.googleauthor성창호-
dc.contributor.googleauthor서우영-
dc.relation.code2012218877-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF MEDICINE[S]-
dc.sector.departmentDEPARTMENT OF MEDICINE-
dc.identifier.pidsungih-
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE