745 0

Decoration of Carbon Nanotube Films with Iridium Nanoparticles and Their Electrochemical Characterization

Title
Decoration of Carbon Nanotube Films with Iridium Nanoparticles and Their Electrochemical Characterization
Author
성기훈
Keywords
Electrocatalysis; Iridium nanoparticles; Carbon nanotubes; Electrochemical deposition; Glucose
Issue Date
2014-06
Publisher
KOREAN BIOCHIP SOCIETY-KBCS, KOREA SCI & TECHNOL CENT, #310, 635-4, YEOGSAM-DONG, KANGNAM-GU, SEOUL, 135-703, SOUTH KOREA
Citation
BIOCHIP JOURNAL, 권: 8, 호: 2, 페이지: 129-136
Abstract
We report the development of a novel nonenzymatic glucose sensor based on single-walled carbon nanotube film electrodes coated with iridium nano-particles (IrNPs-SWCNT). The SWCNT film electrode was first loaded with iridium nanoparticles (IrNPs) by an easily controllable chronocoulometry technique. The SWCNT film electrode coated with IrNPs was characterized by field emission scanning electron microscopy and electrochemical techniques like cyclic voltammetry (CV) and amperometry. There was no current response for glucose oxidation in neutral and acidic media, but a couple of oxidative and reductive peaks were observed when the IrNPs-SWCNT electrode was scanned in alkaline media, showing the strong electrocatalytic activity toward glucose oxidation. Amperometric measurements showed a high sensitivity of 63 mu Acm(-2) mM(-1) and a detection limit of 17 mu M; further, the measurements showed a linear range of 0.59-14 mM. To improve the selectivity of the electrode, the prepared IrNPs-SWCNT film electrode was coated using a 1.0% Nafion aqueous solution. When the electrodes were exposed to interfering substances such as uric acid and ascorbic acid, there were no significant signals observed from these substances, indicating that Nafion is an effective permselective polymer barrier. The sensitivity of the Nafion-coated electrode was 23 mu Acm(-2) mM(-1) and the detection limit was 47 mu M. In addition, the electro-catalytic activity of the Nafion-coated electrode was still stable after 50 cycles in the presence of a 3.0 mM glucose solution. as measured by CV.
URI
http://link.springer.com/article/10.1007/s13206-014-8208-xhttp://hdl.handle.net/20.500.11754/56466
ISSN
1976-0280; 2092-7843
DOI
10.1007/s13206-014-8208-x
Appears in Collections:
GRADUATE SCHOOL[S](대학원) > ETC
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.