Development of the Detection Threshold Concept from a Close Look at Sorption Occurrence Inside a Glass Vial Based on the In-Vial Vaporization of Semivolatile Fatty Acids

Title
Development of the Detection Threshold Concept from a Close Look at Sorption Occurrence Inside a Glass Vial Based on the In-Vial Vaporization of Semivolatile Fatty Acids
Author
김기현
Keywords
VOLATILE ORGANIC-COMPOUNDS; LOOP STRIPPING ANALYSIS; EXPERIMENTAL BIASES; GAS-CHROMATOGRAPHY; HEADSPACE ANALYSIS; MASS-SPECTROMETRY; SORBENT TUBES; WATER; SURFACE; SILICA
Issue Date
2014-07
Publisher
American Chemical Society
Citation
Analytical chemistry, 2014, 86(13), P.6640-6647
Abstract
Headspace (HS) analysis has been recommended as one of the most optimal methods for extracting and analyzing volatile organic compounds from samples in diverse media such as soil and water. Short-chain volatile fatty acids (VFA, C-3-C-7) with strong adsorptivity were selected as the target compounds to assess the basic characteristics of the HS analysis through simulation of HS conditions by in-vial vaporization of liquid-phase standards (VL) in 25 mL glass vials. The reliability of the VL approach was assessed by apportioning the in-vial VFA mass into three classes: (1) vaporized fraction, (2) dynamic adsorption on the vial walls (intermediate stage between vaporization and irreversible absorption), and (3) irreversible absorptive loss (on the vial wall). The dynamic adsorption partitioning inside the vial increased with n-VFA carbon number, e.g., 43% (C-2: acetic acid, extrapolated value), 65% (C-3: propanoic acid), and 98% (C-7: heptanoic acid). The maximum irreversible losses for the studied n-VFAs exhibited a quadratic relationship with carbon number. If the detection threshold limit (DTL: the onset of mass detection after attaining the maximum irreversible loss) is estimated, the DTL values for target VFAs were in the range of 101 ng for i-valeric acid to 616 ng for propionic acid, which are larger than the method detection limit by about 3 orders of magnitude. Consequently, quantitation of VFAs using the VL approach should be critically assessed by simultaneously considering the DTL criterion and the initial VFA masses loaded into the vial.
URI
http://pubs.acs.org/doi/10.1021/ac501382ehttp://hdl.handle.net/20.500.11754/53547
ISSN
0003-2700
DOI
10.1021/ac501382e
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > CIVIL AND ENVIRONMENTAL ENGINEERING(건설환경공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE