267 0

Can the new McGrath laryngoscope rival the GlideScope Ranger portable video laryngoscope? A randomized manikin study

Title
Can the new McGrath laryngoscope rival the GlideScope Ranger portable video laryngoscope? A randomized manikin study
Author
최혁중
Keywords
SIMULATED DIFFICULT AIRWAY; SERIES 5 VIDEOLARYNGOSCOPE; MACINTOSH LARYNGOSCOPE; CONTROLLED-TRIAL; TRACHEAL INTUBATION; AP ADVANCE; ANESTHETISTS
Issue Date
2014-10
Publisher
Elsevier Science INC
Citation
American Journal Of Emergency Medicine, 2014, 32(10), P.1225 - 1229
Abstract
Purpose: We hypothesized that novices would be able to use the McGrath MAC (Aircraft Medical Ltd, Edinburgh, UK) equally as well as the GlideScope Ranger (Verathon, Inc, Bothell, WA) for intubation in regular simulated airways. Methods: We performed a prospective, randomized crossover study of 39 medical students using the McGrath MAC, GlideScope Ranger, and Macintosh in a manikin with 2 normal airways. The primary outcome was the intubation time. Secondary outcomes included the success rates and the overall glottic view of the 3 laryngoscopes. Results: The mean intubation times for each attempt with the McGrath MAC were 30.8 +/- 16.9 seconds or less and did not differ significantly from those obtained with the GlideScope Ranger or the Macintosh in both airway scenarios (P = .18; P = .49). The mean success rates at each attempt with the McGrath MAC were 82.0% +/- 38.8% or more, equal to the Macintosh and the GlideScope Ranger in both scenarios (P = .026; P = .72) except during the first intubation attempt in a normal airway (P =. 008). The median grades of the glottic view visible at each intubation attempt with the McGrath Mac were Cormack-Lehane grade 1 (scenario 1: interquartile range, 1-1; scenario 2: interquartile range, 1-2), which was significantly better than the Macintosh laryngoscope in both scenarios. However, the McGrath Mac did not produce a better glottic view than the GlideScope Ranger with either scenario. Conclusions: The intubation performance of novices using the McGrath MAC was equal to their performance using the GlideScope Ranger in regular simulated airways. (C) 2014 The Authors. Published by Elsevier Inc.
URI
https://linkinghub.elsevier.com/retrieve/pii/S0735675714005270
ISSN
0735-6757
DOI
10.1016/j.ajem.2014.07.034
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE