dc.description.abstractIn an effort to improve the accuracy of measurement techniques for methylmercury (MeHg), the possible experimental bias in its analysis by the gold amalgamation method was investigated with special reference to gaseous elemental mercury (GEM). To this end, a series of calibration experiments were conducted using liquid-phase standards of MeHg prepared at four concentrations (2, 4, 10, and 20 ng mu L-1) at each of four injection volumes (between 0.2 and 2 mu L). Calibration results of MeHg were then examined mainly in terms of two calibration approaches: a fixed standard concentration (FSC) method (variable volumetric injection of standards prepared at a given concentration) and fixed standard volume (FSV) method (injection of multiple standards with varying concentrations at a given volume). The calibration results of MeHg, when evaluated against those of GEM, indicate that the FSC-based calibration of the former is unreliable due to the deterioration of linearity with increasing loading volumes of liquid standard. Thus it is recommended that the FSV approach should be used as the liquid sample loading method to improve the robustness and to minimize the calibration bias of MeHg.en_US
dc.language.isoenen_US
dc.publisherRoyal Society of Chemistryen_US
dc.subjectATOMIC-ABSORPTION-SPECTROMETRYen_US
dc.subjectAMBIENT AIRen_US
dc.subjectMERCURY DETERMINATIONen_US
dc.subjectSEQUENTIAL INJECTIONen_US
dc.subjectGAS-CHROMATOGRAPHYen_US
dc.subjectELEMENTAL MERCURYen_US
dc.subjectVAPORen_US
dc.subjectSYSTEMen_US
dc.subjectVALIDATIONen_US
dc.subjectBIASen_US
dc.titleMajor sources of uncertainties in the analysis of methylmercury using gold amalgamation samplingen_US
dc.typeArticleen_US
dc.relation.no12-
dc.relation.volume5-
dc.identifier.doi10.1039/C3AY40243F-
dc.relation.page3068-3073-
dc.relation.journalANALYTICAL METHODS-
dc.contributor.googleauthorKim, Ki-Hyun-
dc.contributor.googleauthorPhan, Nhu-Thuc-
dc.contributor.googleauthorKim, Yong-Hyun-
dc.contributor.googleauthorYoon, Hye-On-
dc.contributor.googleauthorBrown, Richard J. C.-
dc.relation.code2013000543-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF CIVIL AND ENVIRONMENTAL ENGINEERING-
dc.identifier.pidkkim61-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > CIVIL AND ENVIRONMENTAL ENGINEERING(건설환경공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE