Comparison of serum cystatin C and creatinine as a marker for early detection of decreasing glomerular filtration rate in renal transplants
- Title
- Comparison of serum cystatin C and creatinine as a marker for early detection of decreasing glomerular filtration rate in renal transplants
- Author
- 권오정
- Keywords
- Kidney transplantation; Creatinine; Cystatin C
- Issue Date
- 2012-08
- Publisher
- The Korean Surgical Society, 2012.
- Citation
- Annals of Surgical Treatment and Research(대한외과학회지), Vol.83 No.2, p.69-74
- Abstract
- Purpose: We wished to compare the clinical effectiveness of cystatin C (CyC) and serum creatinine (sCr) to assess renal function in renal transplantation patients. Methods: We compared the clinical effectiveness of CyC with that of the sCr to estimate 24-hour urine creatinine clearance (CrCl) in 72 adult recipients who underwent renal transplantation from January 2001 to December 2008. We analyzed the data in terms of accuracy, bias, precision and sensitivity as a function of length of time posttransplantation and CrCl value. Results: The patients were divided into four groups according to CrCl value <30, <60, <90, and ≥90 mL/min/1.73 m2. The corresponding Cr-based glomerular filtration rate (GFR) estimates had accuracies of 0.71, 0.906, 0.963, and 1.00 within 50% of the reference, with biases (mean percentage errors) of 4.7, 5.32,-5.79,-31.33 mL/min/1.73 m2, and precisions (mean absolute percentage errors) of 7.57, 10.03, 14.52, and 31.33 mL/min/1.73 m2, respectively. The CyC-based GFR estimates had accuracies of 0.35, 0.79, 0.93, and 0.67 within 50% of the reference, respectively, with biases of 15.03, 13.37,-5.58, and-34.79 mL/min/1.73 m2 and precisions of 15.03, 14.80, 17.91, and 34.79 mL/min/1.73 m2. The sensitivity for detecting GFR below 60 mL/min/1.73 m2 was higher for CyC (0.96, 1, and 0.95) than for Cr (0.77, 0.75, and 0.82). Conclusion: CyC is a more sensitive indicator of low GFR (CrCl <60 mL/min/1.73 m2) than sCr. However, CyC-based GFR estimates are restrictive data, and are neither accurate nor specific. Therefore, to evaluate renal function, we may need a revised CyC-based GFR formula and close monitoring of sCr.
- URI
- http://www.dbpia.co.kr/Journal/ArticleDetail/NODE01964883http://hdl.handle.net/20.500.11754/43408
- ISSN
- 2233-7903; 2093-0488
- DOI
- 10.4174/jkss.2012.83.2.69
- Appears in Collections:
- COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
- Files in This Item:
There are no files associated with this item.
- Export
- RIS (EndNote)
- XLS (Excel)
- XML