539 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author김찬형-
dc.date.accessioned2017-03-27T06:21:34Z-
dc.date.available2017-03-27T06:21:34Z-
dc.date.issued2015-07-
dc.identifier.citationAnnals of the ICRP (International Commission on Radiological Protection), v. 45, Page. 188-201en_US
dc.identifier.issn0146-6453-
dc.identifier.issn1872-969x-
dc.identifier.urihttp://journals.sagepub.com/doi/full/10.1177/0146645315626036-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/26340-
dc.description.abstractThe International Commission on Radiological Protection (ICRP) reference male and female adult phantoms, described in Publication 110, are voxel phantoms based on whole-body computed tomography scans of a male and a female patient, respectively. The voxel in-plane resolution and the slice thickness, of the order of a few millimetres, are insufficient for proper segmentation of smaller tissues such as the lens of the eye, the skin, and the walls of some organs. The calculated doses for these tissues therefore present some limitations, particularly for weakly penetrating radiation. Similarly, the Publication 110 phantoms cannot represent 8–40-µm-thick target regions in respiratory or alimentary tract organs. Separate stylised models have been used to represent these tissues for calculation of the ICRP reference dose coefficients (DCs). ICRP Committee 2 recently initiated a research project, the ultimate goal of which is to convert the Publication 110 phantoms to a high-quality polygon-mesh (PM) format, including all source and target regions, even those of the 8–40-µm-thick alimentary and respiratory tract organs. It is expected that the converted phantoms would lead to the same or very similar DCs as the Publication 110 reference phantoms for penetrating radiation and, at the same time, provide more accurate DCs for weakly penetrating radiation and small tissues. Additionally, the reference phantoms in the PM format would be easily deformable and, as such, could serve as a starting point to create phantoms of various postures for use, for example, in accidental dose calculations. This paper will discuss the current progress of the phantom conversion project and its significance for ICRP DC calculations.en_US
dc.language.isoenen_US
dc.publisherElsevieren_US
dc.subjectReference phantomen_US
dc.subjectVoxelen_US
dc.subjectPolygon meshen_US
dc.subjectEffective doseen_US
dc.titleThe reference phantoms: voxel vs polygonen_US
dc.typeArticleen_US
dc.relation.volume45-
dc.relation.page188-201-
dc.relation.journalAnnals of the ICRP (International Commission on Radiological Protection)-
dc.contributor.googleauthorKim, C.H.-
dc.contributor.googleauthorYeom, Y.S.-
dc.contributor.googleauthorNguyen, T.T.-
dc.contributor.googleauthorWang, Z.J.-
dc.contributor.googleauthorKim, H.S.-
dc.contributor.googleauthorHan, M.C.-
dc.contributor.googleauthorLee, J.K.-
dc.contributor.googleauthorZankl, M.-
dc.contributor.googleauthorPetoussi-Henss, N.-
dc.contributor.googleauthorBloch, W.E.-
dc.relation.code2015018698-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDEPARTMENT OF NUCLEAR ENGINEERING-
dc.identifier.pidchkim-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > NUCLEAR ENGINEERING(원자력공학과) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE