375 91

Comparisons of the Pentax-AWS, Glidescope, and Macintosh Laryngoscopes for Intubation Performance during Mechanical Chest Compressions in Left Lateral Tilt: A Randomized Simulation Study of Maternal Cardiopulmonary Resuscitation

Title
Comparisons of the Pentax-AWS, Glidescope, and Macintosh Laryngoscopes for Intubation Performance during Mechanical Chest Compressions in Left Lateral Tilt: A Randomized Simulation Study of Maternal Cardiopulmonary Resuscitation
Author
강형구
Keywords
CARDIAC-ARREST; AIRWAY MANAGEMENT; PREGNANT PATIENT; MANNEQUIN; QUALITY; DISPLACEMENT; DESATURATION; GUIDELINES; RESCUERS; POSITION
Issue Date
2015-06
Publisher
HINDAWI PUBLISHING CORPORATION
Citation
BIOMED RESEARCH INTERNATIONAL, Page. 1-8
Abstract
Purpose. Rapid advanced airway management is important in maternal cardiopulmonary resuscitation (CPR). This study aimed to compare intubation performances among Pentax-AWS (AWS), Glidescope (GVL), and Macintosh laryngoscope (MCL) during mechanical chest compression in 15 degrees and 30 degrees left lateral tilt. Methods. In 19 emergency physicians, a prospective randomized crossover study was conducted to examine the three laryngoscopes. Primary outcomes were the intubation time and the success rate for intubation. Results. The median intubation time using AWS was shorter than that of GVL and MCL in both tilt degrees. The time to visualize the glottic view in GVL and AWS was significantly lower than that of MCL (all P < 0.05), whereas there was no significant difference between the two video laryngoscopes (in 15 degrees tilt, P = 1; in 30 degrees tilt, P = 0.71). The progression of tracheal tube using AWS was faster than that of MCL and GVL in both degrees (all P < 0.001). Intubations using AWS and GVL showed higher success rate than that of Macintosh laryngoscopes. Conclusions. The AWS could be an appropriate laryngoscope for airway management of pregnant women in tilt CPR considering intubation time and success rate.
URI
https://www.hindawi.com/journals/bmri/2015/975649/http://hdl.handle.net/20.500.11754/25540
ISSN
2314-6133; 2314-6141
DOI
10.1155/2015/975649
Appears in Collections:
COLLEGE OF MEDICINE[S](의과대학) > MEDICINE(의학과) > Articles
Files in This Item:
Comparisons of the Pentax AWS Glidescope and Macintosh Laryngoscopes for Intubation Performance during Mechanical Chest Compressions in Left Latera...Download
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE