357 0

Full metadata record

DC FieldValueLanguage
dc.contributor.author장경영-
dc.date.accessioned2016-08-04T02:09:09Z-
dc.date.available2016-08-04T02:09:09Z-
dc.date.issued2015-02-
dc.identifier.citationULTRASONICS, v. 56, Page. 539-544en_US
dc.identifier.issn0041-624X-
dc.identifier.issn1874-9968-
dc.identifier.urihttp://www.sciencedirect.com/science/article/pii/S0041624X14002947-
dc.identifier.urihttp://hdl.handle.net/20.500.11754/22402-
dc.description.abstractThe higher-order acoustic nonlinear parameters are considered effective damage indices in the field of nondestructive evaluation (NDE). They are defined by using the displacement amplitudes of the fundamental frequency and the harmonics, which are called the absolute nonlinear parameters. Generally, however, it is difficult to measure the very small displacement amplitudes of high-frequency harmonics. Therefore, the simplified parameters using the detected wave signal amplitudes, which are known as the relative nonlinear parameters, have been widely used, although their applications are limited to the relative comparison of before and after damage of a single material under consistent experimental circumstances. In this paper, in order to make clear the concept of relative parameter, we presented first that the relative ratio of the simplified parameters is identical to that of the absolute parameters when the detected signal amplitudes are linearly proportional to the actual displacement amplitudes with respect to the fundamental frequency and the harmonics. In addition, the new relationship between the relative ratio of simplified second-order parameter and the relative ratio of simplified third-order parameter was derived from the relationship between the absolute second-and third-order parameters. This new relationship was successfully verified based on experimental results obtained from Al 6061-T6 processed for different heat treatment times, where it was confirmed in advance that the PZT detection signal amplitudes at the fundamental frequency and its second-and third-order harmonics were linearly proportional to the displacement amplitudes. (C) 2014 Elsevier B.V. All rights reserved.en_US
dc.description.sponsorshipNuclear Power Research and Development Program through the National Research Foundation of Korea (NRF) - Ministry of Science, ICT & Future Planningen_US
dc.language.isoenen_US
dc.publisherELSEVIER SCIENCE BVen_US
dc.subjectAcoustic nonlinearityen_US
dc.subjectRelative measurementen_US
dc.subjectThermal agingen_US
dc.subjectMaterial degradationen_US
dc.subjectSimplified nonlinear parameteren_US
dc.titleRelationship between second- and third-order acoustic nonlinear parameters in relative measurementen_US
dc.typeArticleen_US
dc.relation.volume56-
dc.identifier.doi10.1016/j.ultras.2014.10.009-
dc.relation.page539-544-
dc.relation.journalULTRASONICS-
dc.contributor.googleauthorRen, Gang-
dc.contributor.googleauthorKim, Jongboem-
dc.contributor.googleauthorJhang, Kyung-Young-
dc.relation.code2015001185-
dc.sector.campusS-
dc.sector.daehakCOLLEGE OF ENGINEERING[S]-
dc.sector.departmentDIVISION OF MECHANICAL ENGINEERING-
dc.identifier.pidkyjhang-
Appears in Collections:
COLLEGE OF ENGINEERING[S](공과대학) > MECHANICAL ENGINEERING(기계공학부) > Articles
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE