dc.description.abstractBackground: A screw-shaped electrode can offer a compromise between signal quality and invasiveness. However, the standard screw electrode can be vulnerable to electrical noise while directly contact with the skull or skin, and the feasibility and stability for chronic implantation in primate have not been fully evaluated.New Method: We designed a novel screw electrocorticogram (ECoG) electrode composed of three parts: recording electrode, insulator, and nut. The recording electrode was made of titanium with high biocompatibility and high electrical conductivity. Zirconia is used for insulator and nut to prevent electrical noise.Result In computer simulations, the screw ECoG with insulator showed a significantly higher performance in signal acquisition compared to the condition without insulator. In a non-human primate, using screw ECoG, clear visual-evoked potential (VEP) waveforms were obtained, VEP components were reliably maintained, and the electrode's impedance was stable during the whole evaluation period. Moreover, it showed higher SNR and wider frequency band compared to the electroencephalogram (EEG). We also observed the screw ECoG has a higher sensitivity that captures different responses on various stimuli than the EEG.Comparison: The screw ECoG showed reliable electrical characteristic and biocompatibility for three months, that shows great promise for chronic implants. These results contrasted with previous reports that general screw electrode was only applicable for acute applications.Conclusion: The suggested electrode can offer whole-brain monitoring with high signal quality and minimal invasiveness. The screw ECoG can be used to provide more in-depth understanding, not only relationship between functional networks and cognitive behavior, but also pathomechanisms in brain diseases.en_US
dc.description.sponsorshipThis research was supported by the Brain Research Program through the National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT & Future Planning 2016M3C7A1904987.en_US
dc.language.isoen_USen_US
dc.publisherELSEVIER SCIENCE BVen_US
dc.subjectElectrocorticogramen_US
dc.subjectEpidural ECoGen_US
dc.subjectScrew ECoGen_US
dc.subjectInsulationen_US
dc.titleLong-term evaluation and feasibility study of the insulated screw electrode for ECoG recordingen_US
dc.typeArticleen_US
dc.relation.volume308-
dc.identifier.doi10.1016/j.jneumeth.2018.06.027-
dc.relation.page261-268-
dc.relation.journalJOURNAL OF NEUROSCIENCE METHODS-
dc.contributor.googleauthorChoi, Hoseok-
dc.contributor.googleauthorLee, Seho-
dc.contributor.googleauthorLee, Jeyeon-
dc.contributor.googleauthorMin, Kyeongran-
dc.contributor.googleauthorLim, Seokbeen-
dc.contributor.googleauthorPark, Jinsick-
dc.contributor.googleauthorAhn, Kyoung-ha-
dc.contributor.googleauthorKim, In Young-
dc.contributor.googleauthorLee, Kyoung-Min-
dc.contributor.googleauthorJang, Dong Pyo-
dc.relation.code2018001961-
dc.sector.campusS-
dc.sector.daehakGRADUATE SCHOOL OF BIOMEDICAL SCIENCE AND ENGINEERING[S]-
dc.identifier.piddongpjang-
Appears in Collections:
GRADUATE SCHOOL OF BIOMEDICAL SCIENCE AND ENGINEERING[S](의생명공학전문대학원) > ETC
Files in This Item:
There are no files associated with this item.
Export
RIS (EndNote)
XLS (Excel)
XML


qrcode

Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.

BROWSE